-+ 0.00%
-+ 0.00%
-+ 0.00%
Qiming Medical-B (02500): First global release of 6-month clinical follow-up data from the CARDIOVALVE TR system TARGET study
Share
Listen to the news

Zhitong Finance App News, Qiming Medical-B (02500) announced that recently, the 6-month full cohort clinical follow-up data from the TARGET study of its self-developed innovative medical device Cardiovalve tricuspid valve replacement system (CardioValveTR System) was first released globally at PCR London Valves 2026 (London Valve Association 2026).

The TARGET study is a prospective, single-arm, multicenter clinical study mainly used to evaluate the safety and clinical performance of the CardioValveTR system. The study included a total of 157 patients from nearly 30 cardiovascular centers in Germany, Spain, Italy, the United Kingdom and Canada.

Research results showed that the Cardiovalve TR system simultaneously reached the main performance end point and the main safety end point. The proportion of patients with no or minor tricuspid valve reflux 6 months after surgery reached 76.7% (120 samples could be evaluated in the implant group), and continued until 3 years after surgery (76.9%, 26 samples could be evaluated). The patient's functional status, exercise capacity, and quality of life improved early after implantation, and maintained during the follow-up period: walking distance improved by an average of 42 meters in 1 year and 6 minutes after surgery, and the Kansas City Cardiomyopathy Questionnaire (KCCQ) score increased by an average of 20 points; in terms of improving cardiac function by the New York Heart Association (NYHA) 3 years after surgery, the NYHA grade I/II ratio increased from a baseline of 39.9% to 80%. The right ventricular system showed positive and reverse remodeling, with an average decrease of 25%, 22%, and 11% of the internal diameter of the lower ventricle in the 3 years after surgery, the middle and basal segments of the right ventricular end diastolic diameter, respectively. In terms of safety, 30 days after surgery, the all-cause mortality rate was 5.7%, the re-hospitalization rate for heart failure was 1.9%, and the incidence of major pathways and vascular damage requiring surgical intervention was 5.1%. Compared with first-generation delivery systems, the incidence of major bleeding events in the enhanced delivery system decreased from 21% to 5.0%, and the incidence of major vascular complications from 8.8% to 3.0%.

The Cardiovalve TR System is a self-developed transcatheter tricuspid valve replacement product. Compared to similar products, the CardioValvetR system's approach through the femoral vein significantly improves treatment safety. The maximum 55mm large valve ring design can cover about 95% of the patient population; the unique short valve holder design effectively reduces the risk of ventricular outflow obstruction; the operation process is simple, requiring only three steps of positioning, anchoring and release, and has good safety and reproducibility.

The full cohort results of the TARGET study for 6 months and follow-up data for up to 3 years further verified the continued clinical benefits and long-term durability of the Cardiovalve TR system in high-risk and severe tricuspid valve reflux patients. Relying on safety improvements brought about by the self-developed transfemoral intravenous approach design and enhanced delivery system, and with the R&D, production and sales advantages established by the Group in the field of global structural heart disease, the Group will continue to actively promote the CE certification registration process and clinical promotion application of this product to benefit patients around the world.


Disclaimer:Webull uses external vendor Google Translation Service for news translations where we endeavour to ensure these are correct, however, we recommend that you please double-check this information accordingly. Webull is not responsible for translation errors or issues.